1
USB Autoscope IV including:
USB 2.0 A/B interface cable, USB cable hanger, power supply cable;
CD with software.
Automotive diagnostic oscilloscope
3
Universal cable (4 pieces)
Is used for connection to the USB Autoscope IV measuring adapters and / or transducers.
4
Measuring adapter (4 pieces)
For connecting of analog inputs 1 … 6 of the USB Autoscope IV to the car wiring (used together with a universal cable and probe).
5
DIS Cx 6 capacitive probes
To get voltage waveforms from the high-voltage wires of the secondary circuit of distributor and distributorless ignition systems.
6
Sync synchronization transducer
To synchronize to a cylinder by attaching to a plug wire.
7
Cx-M universal capacitive probe
To get voltage waveforms from the secondary circuit of unshielded individual coils ignition systems, as well as from systems where the ignition coil is located inside the distributor.
8
Lx-M universal inductive probe
To get voltage waveforms from the secondary circuit of shielded coils of individual ignition systems, as well as from DIS-ignition coils mounted directly above the spark plugs.
9
Px35 in cylinder pressure transducer
Designed to measure the gas pressure in the range -0.95 … + 35 Bar (-14 – 508 psi). The main purpose of the transducer is to obtain the pressure waveform in the cylinder of the gasoline engine without combustion.
10
PxLonger deep well adapter for high pressure (in cylinder) transducer
Is used to install the pressure transducer in cylinders where the spark plugs are deeply recessed.
11
Spark Gap high voltage spark gap tester
Is used in place of the spark plug when performing in cylinder pressure transducer testing. Also for ignition system testing.
12
Dx vacuum transducer
Designed for vacuum measurement of gases in the range -0.95 … + 0.15 Bar (-14 to 2.2 psi). The main purpose of the sensor is obtaining of the vacuum waveform in the intake manifold of the engine.
13
Insulation piercing probe (2 pieces)
For piercing wiring when performing tests. Causes minimal damage to the wiring. The piered wire should be sealed with a suitable sealer, however.
16
Small alligator clip (2 pieces)
For connection of the measuring adapter with the vehicle wiring (without damage to the wiring, through the open terminals).
1
USB Autoscope III including:
USB 2.0 A/B interface cable, CD with software
Automotive diagnostic oscilloscope.
2
Oscilloscope probe (2 pieces)
For connecting analog inputs 1 … 6 USB Autoscope III to the vehicle wiring.
3
Dx vacuum transducer
Designed for vacuum measurement of gases in the range -0.95 … + 0.15 Bar (-14 to 2.2 psi). The main purpose of the sensor is obtaining of the vacuum waveform in the intake manifold of the engine.
4
Ignition Adapter for ignition system diagnosing, connecting cable PIN5-PIN5
Designed to condition the signal from the secondary ignition probes for connection to normal oscilloscope inputs.
5
Cx capacitive transducer
To get voltage waveforms from the coil wire in distributor type ignition systems.
6
Sync synchronization transducer
To synchronize to a cylinder by attaching to a plug wire.
7
DIS Cx 6 capacitive probes
To get voltage waveforms from the high-voltage wires of the secondary circuit of distributor and distributorless ignition systems.
8
Cx-M universal capacitive probe
To get voltage waveforms from the secondary circuit of unshielded individual coils ignition systems, as well as from systems where the ignition coil is located inside the distributor.
9
Lx-M universal inductive probe
To get voltage waveforms from the secondary circuit of shielded coils of individual ignition systems, as well as from DIS-ignition coils mounted directly above the spark plugs.
10
Dx Amplifier for vacuum transducer
To AC couple and amplify the waveform from the Dx vacuum transducer.
11
Px35 in cylinder pressure transducer
Designed to measure the gas pressure in the range -0.95 … + 35 Bar (-14 – 508 psi). The main purpose of the transducer is to obtain the pressure waveform in the cylinder of the gasoline engine without combustion.
1
PxLonger deep well adapter for high pressure (in cylinder) transducer
Is used to install the pressure transducer in cylinders where the spark plugs are deeply recessed.
2
Spark Gap high voltage spark gap tester
Is used in place of the spark plug when performing in cylinder pressure transducer testing. Also for ignition system testing.
4
Insulation piercing probe (2 pieces)
For piercing wiring when performing tests. Causes minimal damage to the wiring. The piered wire should be sealed with a suitable sealer, however.
5
Small alligator clip (2 pieces)
For connection of the measuring adapter with the vehicle wiring (without damage to the wiring, through the open terminals).
7
APPA 32
Current transducer with two ranges of measurement:
±100A, where the output is 10mV/A.
±600A, where the output is 1mV/A.
10
CTi
Current transducer with two ranges of measurement:
-4A…+10A, where the output is 500mV/A.
-20A…+50A, where the output is 100mV/A.
Minimum measurable current 100 mA.
Maximum diameter of the measured conductor is 4 mm.
11
Laser
External optical crankshaft sensor.
Intended to diagnose using the script CSS of engines that are not equipped with a crankshaft sensor.
12
Paint Thickness Gauge
This gauge is used to detect the paint thickness on vehicle panels.
13
Universal cable extension
This extension lead is used when longer reach than what is provided by the normal test leads are needed.
14
PIN3-BNC
This adapter is used when it is desired to use test leads or equipment equipped with BNC connectors with USB Autoscope IV.
15
Adapter for high voltage extension cable
Designed for making your own coil or plug extension cables.
16
Lambda Meter
Wide band Lambda probe with controller has a display that shows the numerical value of the λ (Lambda) coefficient.
The output signal of the controller can be connected to the input of an USB Autoscope in order to see a waveform of the air-fuel mix composition.